Accuracy of first-trimester ultrasound in diagnosis of intrauterine pregnancy prior to visualization of the yolk sac: a systematic review and meta-analysis

Ultrasound Obstet Gynecol. 2015 Aug;46(2):142-9. doi: 10.1002/uog.14725. Epub 2015 Jun 29.

Abstract

Objectives: To evaluate the diagnostic accuracy of ultrasound in predicting the location of an intrauterine pregnancy before visualization of the yolk sac is possible.

Methods: This was a systematic review conducted in accordance with the PRISMA statement and registered with PROSPERO. We searched MEDLINE, EMBASE and The Cochrane Library for relevant citations. Studies were selected in a two-stage process and their data extracted by two reviewers. Accuracy measures were calculated for each ultrasound sign, i.e. gestational sac, double decidual sac sign, intradecidual sign, chorionic rim sign and yolk sac. Individual study estimates were plotted in summary receiver-operating characteristics curves and forest plots for examination of heterogeneity. The quality of included studies was assessed.

Results: Seventeen studies including 2564 women were selected from 19 959 potential papers. Following meta-analysis, the presence of a gestational sac on ultrasound examination was found to predict an intrauterine pregnancy with a sensitivity of 52.8% (95% CI, 38.2-66.9%) and specificity of 97.6% (95% CI, 94.3-99.0%). The corresponding performance of the double decidual sac sign, intradecidual sign, chorionic rim sign and yolk sac were: 81.8% (95% CI, 68.1-90.4%) and 97.3% (95% CI, 76.1-99.8%); 66.1% (95% CI, 58.9-72.8%) and 100% (95% CI, 91.0-100%); 79.9% (95% CI, 73.0-85.7%) and 97.1% (95% CI, 89.9-99.6%); and 42.2% (95% CI, 27.7-57.9%) and 100% (95% CI, 54.1-100%), respectively.

Conclusion: Visualization of a gestational sac, double decidual sac sign, intradecidual sign or chorionic rim sign increases the probability of an intrauterine pregnancy but is not as accurate for diagnosis as the detection of the yolk sac. However, the findings were limited by the small number and poor quality of the studies included and heterogeneity in the index test and reference standard.

Keywords: QUADAS-2; diagnostic accuracy; intrauterine; pregnancy; systematic review; ultrasound.

Publication types

  • Meta-Analysis
  • Research Support, Non-U.S. Gov't
  • Review
  • Systematic Review

MeSH terms

  • Decidua / diagnostic imaging
  • Female
  • Gestational Sac / diagnostic imaging*
  • Humans
  • Pregnancy
  • Pregnancy Trimester, First
  • Pregnancy, Ectopic / diagnostic imaging
  • Pregnancy, Ectopic / prevention & control
  • Ultrasonography, Prenatal / methods*
  • Yolk Sac / diagnostic imaging*