Kinetic analysis of the translocator protein positron emission tomography ligand [18F]GE-180 in the human brain

Eur J Nucl Med Mol Imaging. 2016 Nov;43(12):2201-2210. doi: 10.1007/s00259-016-3444-z. Epub 2016 Jun 28.

Abstract

Purpose: PET can image neuroinflammation by targeting the translocator protein (TSPO), which is upregulated in activated microglia. The high nonspecific binding of the first-generation TSPO radioligand [11C]PK-11195 limits accurate quantification. [18F]GE-180, a novel TSPO ligand, displays superior binding to [11C]PK-11195 in vitro. Our objectives were to: (1) evaluate tracer characteristics of [18F]GE-180 in the brains of healthy human subjects; and (2) investigate whether the TSPO Ala147Thr polymorphism influences outcome measures.

Methods: Ten volunteers (five high-affinity binders, HABs, and five mixed-affinity binders, MABs) underwent a dynamic PET scan with arterial sampling after injection of [18F]GE-180. Kinetic modelling of time-activity curves with one-tissue and two-tissue compartment models and Logan graphical analysis was applied to the data. The primary outcome measure was the total volume of distribution (V T) across various regions of interest (ROIs). Secondary outcome measures were the standardized uptake values (SUV), the distribution volume and SUV ratios estimated using a pseudoreference region.

Results: The two-tissue compartment model was the best model. The average regional delivery rate constant (K 1) was 0.01 mL cm-3 min-1 indicating low extraction across the blood-brain barrier (1 %). The estimated median V T across all ROIs was also low, ranging from 0.16 mL cm-3 in the striatum to 0.38 mL cm-3 in the thalamus. There were no significant differences in V T between HABs and MABs across all ROIs.

Conclusion: A reversible two-tissue compartment model fitted the data well and determined that the tracer has a low first-pass extraction (approximately 1 %) and low V T estimates in healthy individuals. There was no observable dependency on the rs6971 polymorphism as compared to other second-generation TSPO PET tracers. Investigation of [18F]GE-180 in populations with neuroinflammatory disease is needed to determine its suitability for quantitative assessment of TSPO expression.

Keywords: GE180; Kinetic analysis; Neuroinflammation; Positron emission tomography (PET); Quantification; Translocator protein (TSPO).

MeSH terms

  • Adult
  • Algorithms
  • Brain / diagnostic imaging*
  • Brain / metabolism*
  • Carbazoles / pharmacokinetics*
  • Computer Simulation
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Kinetics
  • Metabolic Clearance Rate
  • Middle Aged
  • Models, Neurological
  • Molecular Imaging / methods
  • Positron-Emission Tomography / methods*
  • Radiopharmaceuticals / pharmacokinetics
  • Receptors, GABA / genetics
  • Receptors, GABA / metabolism*
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Carbazoles
  • GE-180
  • Radiopharmaceuticals
  • Receptors, GABA
  • TSPO protein, human