Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year follow-up of a propensity score matching comparison (the BIORESOLVE-ISR Study)

Catheter Cardiovasc Interv. 2018 Oct 1;92(4):668-677. doi: 10.1002/ccd.27473. Epub 2018 Jan 22.

Abstract

Objectives: to compare the 1-year outcome between bioresorbable vascular scaffold (BVS), everolimus-eluting stent (EES), and drug-eluting balloon (DEB) for in-stent restenosis (ISR) treatment.

Background: BVS has been proposed as alternative for ISR treatment. To date a direct comparison between BVS and DES or DEB for ISR treatment is lacking.

Methods: We retrospectively analyzed all ISR lesions treated with BVS, DEB, and EES from January 2012 to December 2014. A total of 548 lesions (498 patients) were included. By applying two propensity-score matching, 93 lesions treated with BVS were compared with 93 lesions treated with DEB, and 100 lesions treated with BVS were compared to 100 lesions treated with EES.

Results: At 1-year follow-up the incidence of device-oriented cardiovascular events (DOCE) and its components did not significantly differ between BVS and DEB (DOCE: 10.9 vs. 11.8%, HR, 0.91; 95% CI, 0.33-2.52; P = 0.86; Cardiac death: 2.2 vs. 1.2%, HR, 1.74, 95% CI 0.16-18.80, P = 0.65; ID-TLR: 8.9 vs. 10.7%, HR, 0.81, 95% CI 0.27-2.48, P = 0.71; TV-MI: 3.3 vs. 1.2%, HR, 2.39, 95% CI 0.27-21.32, P = 0.43) and BVS vs. EES (DOCE: 10.1 vs. 5.2% HR, 1.81, 95% CI, 0.63-5.25; P = 0.27; Cardiac death: 3.0 vs. 1.1%; HR, 2.83, 95% CI 0.29-27.4, P = 0.37; ID-TLR: 7.2 vs. 4.2%, HR, 1.57, 95% CI 0.47-5.23, P = 0.46; TV-MI: 3.1 vs. 0%).

Conclusion: At 1-year follow-up the use of BVS as ISR treatment is associated with a higher, even if not significant, DOCE rate compared with EES while a similar rate compared to DEB.

Keywords: bioresorbable vascular scaffold; drug eluting balloon; drug eluting stent; in stent restenosis; percutaneous coronary intervention.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Angioplasty, Balloon, Coronary / mortality
  • Cardiac Catheters*
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coated Materials, Biocompatible*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology
  • Coronary Restenosis / mortality
  • Coronary Restenosis / therapy*
  • Drug-Eluting Stents*
  • Everolimus / administration & dosage*
  • Everolimus / adverse effects
  • Female
  • Humans
  • Italy
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Propensity Score
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Everolimus