Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation

Heart Vessels. 2019 Mar;34(3):496-502. doi: 10.1007/s00380-018-1254-x. Epub 2018 Oct 9.

Abstract

Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop diameter of 15 or 20 mm. The novel spiral mapping catheter (Achieve Advance, SMC2) was designed as a true guidewire and is available, in addition to the sizes of the SMC1, as a 10-polar mapping catheter with a distal loop diameter of 25 mm. Whether these novel features of SMC2 influence procedural characteristics of Cryo-PVI in comparison to SMC1 has not been reported. In this prospective cohort study 158 patients (age 65.1 ± 12.4 years, female 39%, paroxysmal AF 60%) undergoing PVI with the 2nd generation cryoballoon were included. SMC1 was used in 57 patients (36%), whereas 101 patients (64%) underwent Cryo-PVI with the SMC2. All PVs (623/623, 100%) were isolated successfully. Mean procedure duration was 72.0 ± 18.9 min in the SMC1 group and 74.4 ± 19.1 min in the SMC2 group (p = 0.432). Mean fluoroscopy time was also not different between both study groups (SMC1 15.7 ± 6.6 min, SMC2 15.7 ± 7.3 min, p = 0.593). TTI was observed in 68.6% of pulmonary veins in the SMC1 group, whereas TTI observation rate was 82.6% in the SMC2 group (p < 0.001). Number of freezes (5.5 ± 1.5 vs. 6.5 ± 1.9; p = 0.001) and total freeze duration (14.1 ± 4.5 vs. 17.6 ± 5.6; p < 0.001) were increased in the SMC2 group. SMC2 significantly increases TTI observation rate during Cryo-PVI. Procedure duration and fluoroscopy time are similar and number of freezes and total freeze duration are increased compared to PVI with SMC1 due to decreased stability and maneuverability of SMC2.

Keywords: Achieve advance; Atrial fibrillation; Cryoballoon; Spiral mapping catheter; Time-to-isolation.

MeSH terms

  • Aged
  • Atrial Fibrillation / diagnosis*
  • Atrial Fibrillation / physiopathology
  • Atrial Fibrillation / surgery
  • Catheters*
  • Cryosurgery / instrumentation*
  • Equipment Design
  • Female
  • Fluoroscopy
  • Follow-Up Studies
  • Heart Conduction System / physiopathology
  • Heart Conduction System / surgery*
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Pulmonary Veins / surgery*
  • Time-to-Treatment