The Effect of Support Surfaces on the Incidence of Pressure Injuries in Critically Ill Patients: A Randomized Clinical Trial

Crit Care Res Pract. 2018 Dec 18:2018:3712067. doi: 10.1155/2018/3712067. eCollection 2018.

Abstract

Purpose: To analyze whether a viscoelastic mattress support surface can reduce the incidence of stage 2 pressure injuries compared to a standard hospital mattress with pyramidal overlay in critically ill patients.

Method: A randomized clinical trial with intention-to-treat analysis was carried out recruiting patients with Braden scale ≤14 on intensive care unit admission from April 2016 to April 2017. Patients were allocated into two groups: intervention group (viscoelastic mattress) and control group (standard mattress with pyramidal overlay). The level of significance adopted was 5%.

Results: A total of 62 patients were included in the study. There was a predominance of males (53%) and the mean age was 67.9 (SD 18.8) years. There were no differences in clinical or severity characteristics between the patients in the control group and the intervention group. Pressure injuries occurred in 35 patients, with a median time of 7 days (ITQ 4-10) from admission. The frequency of pressure injuries was higher in the control group (80.6%) compared to the intervention group (32.2%; p < 0.001).

Conclusions: Viscoelastic support surfaces reduced the incidence of pressure injuries in moderate or higher risk critically ill patients when compared to pyramidal support surfaces.