Fluorescence Video Angiography for Evaluation of Dynamic Perfusion Status in an Aneurysm Preclinical Experimental Setting

Oper Neurosurg (Hagerstown). 2019 Oct 1;17(4):432-438. doi: 10.1093/ons/opz011.

Abstract

Background: Experimental studies to assess aneurysm occlusion or perfusion typically rely on macroscopic examination or histological analysis but cannot assess dynamic perfusion.

Objective: To describe an easy-to-implement and inexpensive fluorescence angiographic technique for the in vivo assessment and imaging of the dynamic perfusion status of aneurysms and their underlying blood vessels in a rat model.

Methods: In a rat sidewall aneurysm model, the angiographic setup included 2 bandpass filters, a video camera, and a bicycle spotlight. After 48 rats underwent fluorescein angiography, dissections were performed to confirm the perfusion status by macroscopic and histologic examination of the aneurysm.

Results: Direct injection of 0.2 mL fluorescein 10% Faure achieved strong, clear visibility in all 48 aneurysms. Macro-/microscopic examination identified residual perfusion in 25 and complete healing in 23 aneurysms. Fluorescein imaging identified 21 of these 25 aneurysms (84%) with residual perfusion and 22 of 23 aneurysms (96%) with no residual perfusion.

Conclusion: Our fluorescein imaging technique proved efficient for the evaluation of aneurysm patency and parent artery integrity in this experimental setting. Fluorescein is nontoxic, can be re-administered if needed, and, in this technique, can expand the armamentarium for the preclinical evaluation of dynamic perfusion status.

Keywords: Aneurysm; Experimental; Fluorescein; Fluorescence; Rat; Video angiography.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Aorta, Thoracic / diagnostic imaging*
  • Aorta, Thoracic / transplantation
  • Aortic Aneurysm / diagnostic imaging*
  • Disease Models, Animal
  • Fluorescein Angiography / methods*
  • Intracranial Aneurysm
  • Rats
  • Video Recording