Reliability of a new loaded rolling wheel system for measuring spinal stiffness in asymptomatic participants

BMC Musculoskelet Disord. 2019 Apr 24;20(1):176. doi: 10.1186/s12891-019-2543-y.

Abstract

Background: Few, if any, patient reported symptoms have been shown to be related to objective measures of spine function. Recently, patient-reported measures of disability following spinal manipulative therapy have been associated with an immediate decrease in spinal stiffness obtained by instrumented L3 indentation. Given this novel relation, we anticipate that stiffness measures obtained from locations in addition to L3 may yield valuable information. As such, our research team has developed a new technique to acquire stiffness data continuously over an entire spinal region. The reliability of stiffness measurements obtained by this new technique has yet to be quantified.

Methods: Continuous stiffness testing employs a weighted roller that moves uninterrupted over the spine while measuring the resulting spinal deflection along a subject-specific, laser-defined trajectory. A volunteer sample of asymptomatic participants were assessed in 2 sessions occurring 1 to 4 days apart, with each session scheduled at the same time of day. Each session consisted of 3 trials each beginning at a baseline of ~ 17 N then progressing to a maximally tolerable load as defined from pre-test familiarization trials (~ 61, 72 or 83 N). Reliability was evaluated with the intraclass correlation coefficient, the standard error of measurement and Bland & Altman analysis.

Results: A total of 17 asymptomatic participants (mean age 29.2 +/- 6 years, 53% female) took part in the study. Overall, the within and between-session reliability of lumbar spine stiffness measures at the maximal tolerable load was excellent ranging from 0.95-1.00 and good to excellent ranging from 0.82-0.93, respectively. Trial averaging was found to reduce standard error of measurement by a mean of 35.2% over all measurement conditions compared to a single trial. Bland and Altman plots for agreement in lumbar spine stiffness measurements varied from - 0.3 +/- 1.2 at unloaded condition to - 0.2 +/- 1.2 at loaded condition. Data from two participants were removed due to the development of back pain between two sessions.

Conclusion: This study introduced a new technique for measuring spinal stiffness over an entire spinal region in asymptomatic human participants. The new technique produced reliable measurements quantifying the load-displacement values for within-session and between-session assessments.

Keywords: Reliability; Spine; Stiffness; Test-retest; VerteTrack.

Publication types

  • Evaluation Study

MeSH terms

  • Adult
  • Asymptomatic Diseases*
  • Female
  • Humans
  • Low Back Pain / etiology
  • Low Back Pain / therapy*
  • Male
  • Manipulation, Spinal
  • Reproducibility of Results
  • Spinal Diseases / complications
  • Spinal Diseases / diagnosis*
  • Young Adult