Spleen size improvement in advanced heart failure patients using a left ventricular assist device

Artif Organs. 2020 Jul;44(7):700-708. doi: 10.1111/aor.13658. Epub 2020 Feb 24.

Abstract

The spleen has been recognized as an important organ that holds a reserve of 20% to 30% of the total blood volume. Spleen contraction and splenic volume reduction occur in patients with hypovolemic shock. However, the change in the spleen volume and the association between spleen size and hemodynamic parameters remain unclear in patients with advanced heart failure (HF) who need left ventricular assist device (LVAD) support. This study was performed to investigate the change in spleen size and the relationship between spleen size and hemodynamic parameters before and after LVAD implantation in patients with advanced HF. We enrolled 20 patients with advanced HF on LVAD support. All patients underwent right heart catheterization and computed tomography before and after LVAD implantation. The spleen size was measured by computed tomography volumetry. We excluded patients with a mean right atrial pressure (RAP) of <5 mm Hg because of the possibility of hypovolemia and those with a cardiac index of >2.2 L/min/m2 before LVAD implantation. The splenic volume significantly increased from 160.6 ± 46.9 mL before LVAD implantation to 224.6 ± 73.5 mL after LVAD implantation (P < .001). Before LVAD implantation, there was a significant negative correlation between spleen volume and systemic vascular resistance (SVR). After LVAD implantation, however, there were significant correlations between spleen volume and the cardiac index, RAP, and pulmonary capillary wedge pressure despite the absence of a significant correlation between spleen volume and SVR. Furthermore, one patient developed reworsening HF because of LVAD failure due to pump thrombosis. In this case, the splenic volume was 212 mL before LVAD implantation and increased to 418 mL after LVAD implantation, although it decreased to 227 mL after LVAD failure. The spleen size may change depending on hemodynamics in patients with advanced HF with LVAD support, reflecting sympathetic nerve activity and the systemic volume status.

Keywords: CT volumetry; advanced heart failure; left ventricular assist device; spleen volume.

MeSH terms

  • Adult
  • Cardiac Catheterization / instrumentation*
  • Female
  • Heart Failure / complications
  • Heart Failure / diagnosis
  • Heart Failure / physiopathology
  • Heart Failure / surgery*
  • Heart-Assist Devices*
  • Humans
  • Male
  • Middle Aged
  • Organ Size / physiology
  • Retrospective Studies
  • Severity of Illness Index
  • Spleen / diagnostic imaging
  • Spleen / pathology*
  • Tomography, X-Ray Computed
  • Treatment Outcome
  • Vascular Resistance / physiology