Comparing the diagnostic accuracy of 4D CT and 99mTc-MIBI SPECT/CT for localizing hyperfunctioning parathyroid glands: a systematic review and meta-analysis

Nucl Med Commun. 2021 Mar 1;42(3):225-233. doi: 10.1097/MNM.0000000000001331.

Abstract

Purpose: To compare the diagnostic accuracy of dual-phase 99mTc-MIBI single photon emission computed tomography/computed tomography (SPECT/CT) and 4D CT for the localization of hyperfunctioning parathyroid glands, a systematic review and meta-analysis was performed. Whether 4D CT combined to SPECT/CT [contrast-enhanced (CE)-SPECT/CT] had a better diagnostic performance than SPECT/CT alone in this scenario was also evaluated.

Material and methods: PubMed and Embase databases were searched for eligible studies. To reduce interstudy heterogeneity, only studies with clear head-to-head comparison were included. Publication bias was assessed by the Deeks funnel plot. The pooled sensitivity, specificity and the area under the curve (AUC) for 4D CT, SPECT/CT and CE-SPECT/CT were determined by random-effect analysis, respectively.

Results: Nine studies met the inclusion criteria, with a total of 911 participants. The sensitivity and specificity of 4D CT were 0.85 [95% confidence interval (CI), 0.69-0.94] and 0.93 (95% CI, 0.88-0.96), whereas the sensitivity and specificity for SPECT/CT were 0.68 (95% CI, 0.51-0.82; P = 0.048 compared with 4D CT) and 0.98 (95% CI, 0.95-0.99; P = 0.014 compared with 4D CT), respectively. CE-SPECT/CT is comparable to SPECT/CT in specificity and AUC, but it may improve the sensitivity (although there was a lack of statistical difference, 0.87 vs. 0.78; P = 0.125).

Conclusion: Although 4D CT shows comparable AUC and borderline better sensitivity than SPECT/CT, its clinical application is confined by relatively low specificity and high radiation exposure. CE-SPECT/CT may improve the sensitivity without compromising the specificity and AUC of SPECT/CT.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Four-Dimensional Computed Tomography*
  • Humans
  • Parathyroid Glands / diagnostic imaging*
  • Parathyroid Glands / physiopathology*
  • Sensitivity and Specificity
  • Single Photon Emission Computed Tomography Computed Tomography*
  • Technetium Tc 99m Sestamibi*

Substances

  • Technetium Tc 99m Sestamibi