Novel Brain Protection Method for Zone 0 Endovascular Aortic Repair with Selective Cerebral Perfusion

Ann Vasc Dis. 2021 Jun 25;14(2):153-158. doi: 10.3400/avd.oa.21-00025.

Abstract

Objective: Zone 0 thoracic endovascular aortic repair (TEVAR) is associated with a high incidence of cerebral infarction mostly due to the embolic shower of a plaque from the aortic arch when the stent graft brushes against the aortic wall. Thus, it is important to develop a method for protecting the brain from such embolism. We report the outcomes of Zone 0 TEVAR with a novel brain protection method using selective cerebral perfusion under extracorporeal membrane oxygenation (ECMO). Materials and Methods: Two T-shaped grafts with ringed expanded polytetrafluoroethylene (ePTFE) were created using an 8-mm-ringed ePTFE anastomosed end-to-side with a 7-mm-ringed ePTFE. Carotid-carotid bypass and axillo-axillary bypass were established using these grafts. ECMO was connected to the grafts and the femoral vein. Bilateral carotid and axillary arteries were blocked, and cerebral perfusion was selectively maintained using ECMO. Total endovascular Zone 0 TEVAR was performed. The patency of brachiocephalic artery was maintained using the chimney or in situ fenestration technique. Results: Since August 2016, seven patients with aortic arch aneurysms underwent the procedure. The mortality rate was 0%. No neurological complications developed. Conclusion: This brain protection method using selective cerebral perfusion under ECMO is a safe method for Zone 0 TEVAR.

Keywords: brain protection; endovascular aortic repair; extracorporeal membrane oxygenation; zone 0.