Echocardiography in the time of Covid-19: Ultrasound enhancing agents save time and augment diagnostic information

Int J Cardiol. 2022 Jan 1:346:100-102. doi: 10.1016/j.ijcard.2021.11.040. Epub 2021 Nov 16.

Abstract

Background: There are currently no clear guidelines regarding the use of ultrasound enhancing agents (UEAs) with transthoracic echocardiography (TTE) for patients hospitalized with Covid-19. We investigated whether the performance of TTE with UEAs provides more diagnostic information and allows for shorter acquisition time compared to unenhanced TTE imaging in this patient population.

Methods: We analyzed the TTEs of 107 hospitalized Covid-19 patients between April and June 2020 who were administered UEAs (Definity®, Lantheus). The time to acquire images with and without UEAs was calculated. A level III echocardiographer determined if new, clinically significant findings were visualized with the addition of UEAs.

Results: There was a mean of 11.84±3.59 UEA cineloops/study vs 20.74±8.10 non-UEA cineloops/study (p < 0.0001). Mean time to acquire UEA cineloop images was 72.28±28.18 s/study compared to 188.07±86.04 s/study for non-UEA cineloop images (p < 0.0001). Forty-eight patients (45%) had at least one new finding on UEA imaging, with a total of 62 new findings seen. New information gained with UEAs was more likely to be found in patients with acute respiratory distress syndrome (21 vs 9, p < 0.001) and in those on mechanical ventilation (21 vs 15, p = 0.046).

Conclusions: TTE with UEAs required less time and fewer cineloop images compared to non-UEA imaging in patients hospitalized with Covid-19. Additionally, Covid-19 patients with severe respiratory disease benefited most with regard to new diagnostic information. Health care personnel should consider early use of UEAs in select hospitalized Covid-19 patients in order to reduce exposure and optimize diagnostic yield.

Keywords: Covid-19; Echocardiography; Ultrasound enhancing agents.

MeSH terms

  • COVID-19*
  • Echocardiography
  • Humans
  • SARS-CoV-2
  • Ultrasonography