An All-Suture Anchor Offers Equivalent Clinical Performance to an Established Solid Suture Anchor in the Arthroscopic Repair of Rotator Cuff Tears: A Prospective, Randomized, Multicenter Trial With 12-Month Follow-Up

Arthroscopy. 2024 Feb;40(2):265-276. doi: 10.1016/j.arthro.2023.06.056. Epub 2023 Jul 7.

Abstract

Purpose: To evaluate the safety and efficacy of a next-generation, all-suture anchor in patients undergoing arthroscopic repair of rotator cuff tears, compared with that of an established solid suture anchor.

Methods: Between April 2019 and January 2021, a prospective, comparative, randomized controlled noninferiority study conducted on people with Chinese ethnicity at 3 tertiary hospitals enrolled patients (18-75 years) requiring arthroscopic treatment for rotator cuff tears. Patients were randomized into 2 cohorts receiving either all-suture anchor or solid suture anchor and followed for 12 months. The primary outcome was the Constant-Murley score at the 12-month follow-up. Magnetic resonance imaging assessments determined the rate of retear of rotator cuff repair (defined as Sugaya classification 4 and 5). Safety evaluation was performed at all follow-up points to determine the adverse events (AEs).

Results: In total, 120 patients with rotator cuff tears (mean age, 58.3 years; 62.5% female; 60 receiving all-suture anchor) underwent treatment. Five patients were lost to follow-up. Both cohorts showed significant improvement in Constant-Murley scores between baseline and 6 months (P < .001) and between 6 and 12 months (P < .001). There were no significant differences in Constant-Murley scores between the 2 cohorts at 12 months (P = .122) after operation. The retear rate at 12 months was 5.7% and 1.9% in the all-suture and solid suture anchor cohorts, respectively (P = .618). There were 2 cases of intraoperative anchor pullout, both of which were successfully resolved. No cases of postoperative reoperation or other anchor-related AEs were reported.

Conclusions: The all-suture anchor offered equivalent clinical performance to an established solid suture anchor at the 12-month follow-up in patients undergoing arthroscopic repair of rotator cuff tears. The retear rate was not statistically significantly different between the 2 cohorts.

Level of evidence: Level I, randomized controlled trial.

Publication types

  • Randomized Controlled Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arthroscopy / methods
  • Female
  • Follow-Up Studies
  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Prospective Studies
  • Rotator Cuff / pathology
  • Rotator Cuff / surgery
  • Rotator Cuff Injuries* / pathology
  • Rotator Cuff Injuries* / surgery
  • Suture Anchors
  • Suture Techniques
  • Treatment Outcome