Implant Based Breast Reconstruction Using a Titanium-Coated Polypropylene Mesh (TiLOOP® Bra): A Systematic Review and Meta-analysis

Aesthetic Plast Surg. 2024 Mar;48(5):925-935. doi: 10.1007/s00266-023-03500-1. Epub 2023 Jul 18.

Abstract

Background: Implant-based breast reconstruction (IBBR) can be performed using a variety of biological and synthetic meshes. However, there has yet to be a consensus on the optimal mesh. This study investigates the safety and patient satisfaction of using TiLOOP® Bra in IBBR and compares its postoperative complication risk with that of porcine acellular dermal matrix (ADM) and SERAGYN® BR.

Methods: The literature review was performed via PRISMA criteria, 23 studies met the inclusion criteria for the TiLOOP® Bra review, and 5 studies met the inclusion criteria for the meta-analysis. Patient characteristics and per-breast complications were collected. Data were analyzed using Cochrane RevMan and IBM SPSS.

Results: In 3175 breasts of 2685 patients that underwent IBBR using TiLOOP® Bra, rippling was observed as the most common complication, followed by seroma and capsular contracture. No significant difference in the overall complication rate between pre- and sub-pectoral IBBR using TiLOOP® Bra. However, the meta-analysis showed that the TiLOOP® Bra group had significantly lower odds of implant loss, seroma, wound dehiscence, and the need for reoperation or hospitalization than the ADM group. Additionally, the TiLOOP® Bra group had a significantly lower seroma rate compared to the SERAGYN® BR group, while the other outcome indicators were similar between the two groups.

Conclusion: TiLOOP® Bra has become increasingly popular in IBBR in recent years. This review and meta-analysis support the favorable safety profile of TiLOOP® Bra reported in the current literature. The meta-analysis revealed that TiLOOP® Bra has better safety than ADM and a comparable risk of complications compared to SERAGYN® BR. However, as most studies had low levels of evidence, further investigations are necessary.

Level of evidence iii: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Keywords: Acellular dermal matrix (ADM); Complication; Implant-based breast reconstruction (IBBR); SERAGYN® BR; Titanium-coated polypropylene mesh (TiLOOP® Bra).

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Acellular Dermis*
  • Animals
  • Breast Implantation*
  • Breast Implants*
  • Breast Neoplasms* / surgery
  • Female
  • Humans
  • Mammaplasty*
  • Polypropylenes
  • Postoperative Complications / epidemiology
  • Postoperative Complications / prevention & control
  • Retrospective Studies
  • Seroma
  • Surgical Mesh
  • Swine
  • Titanium
  • Treatment Outcome

Substances

  • Polypropylenes
  • Titanium