Radiofrequency Ablation of Re-entrant Atrial Tachycardia Originating from the Superior Vena Cava with a High-resolution, 3-dimensional Mapping System

J Innov Card Rhythm Manag. 2023 Aug 15;14(8):5546-5551. doi: 10.19102/icrm.2023.14083. eCollection 2023 Aug.

Abstract

An 80-year-old man with no previous history of catheter ablation or cardiac surgery underwent catheter ablation for atrial tachycardia (AT). We suspected that the mechanism causing AT was re-entry indicated by the entrainment phenomenon during AT and through activation mapping with a 3-dimensional mapping system (EnSite™ X EP system; Abbott, Chicago, IL, USA). We used a multipolar catheter (Advisor™ HD Grid Mapping Catheter; Abbott) inserted into the superior vena cava (SVC) to accomplish activation mapping. The AT circuit was localized inside the SVC with a fractionated potential recorded on its right lateral wall. A similar fractionated potential was observed in the surrounding area. These areas functioned as the critical isthmus of the AT. Radiofrequency (RF) catheter ablation at these sites eliminated the tachycardia. After RF delivery, no tachycardia was induced by programmed stimulation, even during isoproterenol infusion. Consequently, there was no recurrence of tachycardia even after catheter ablation.

Keywords: Atrial tachycardia; entrainment pacing; high-resolution 3D mapping; re-entry; superior vena cava.

Publication types

  • Case Reports