Safety and Effectiveness of the High-Sensitivity Cardiac Troponin HEART Pathway in Patients With Possible Acute Coronary Syndrome

Circ Cardiovasc Qual Outcomes. 2024 Mar;17(3):e010270. doi: 10.1161/CIRCOUTCOMES.123.010270. Epub 2024 Feb 8.

Abstract

Background: The HEART Pathway (History, Electrocardiogram, Age, Risk factors, Troponin) can be used with high-sensitivity cardiac troponin to risk stratify emergency department patients with possible acute coronary syndrome. However, data on whether a high-sensitivity HEART Pathway (hs-HP) are safe and effective is lacking.

Methods: An interrupted time series study was conducted at 5 North Carolina sites in 26 126 adult emergency department patients being investigated for possible acute coronary syndrome and without ST-segment-elevation myocardial infarction. Patients were accrued into 16-month preimplementation and postimplementation cohorts with a 6-month wash-in phase. Preimplementation (January 2019 to April 2020), the traditional HEART Pathway was used with 0- and 3-hour contemporary troponin measures (Siemens). In the postimplementation period (November 2020 to February 2022), a modified hs-HP was used with 0- and 2-hour high-sensitivity cardiac troponin (Beckman Coulter) measures. The primary safety and effectiveness outcomes were 30-day all-cause death or myocardial infarction and 30-day hospitalizations. These outcomes and early discharge rate (emergency department discharge without stress testing or coronary angiography) were determined from health records and death index data. Outcomes were compared preimplementation versus postimplementation using χ2 tests and multivariable logistic regression to adjust for potential confounders.

Results: Preimplementation and postimplementation cohorts included 12 317 and 13 809 patients, respectively, of them 52.7% (13 767/26 126) were female with a median age of 54 years (interquartile range, 42-66). Rates of 30-day death or MI were 6.8% (945/13 809) postimplementation and 7.7% (948/12 317) preimplementation (adjusted odds ratio, 1.00 [95% CI, 0.90-1.11]). hs-HP implementation was associated with 19.9% (95% CI, 18.7%-21.1%) higher early discharges (post versus pre: 63.6% versus 43.7%; adjusted odds ratio, 2.22 [95% CI, 2.10-2.35]). The hs-HP was also associated with 16.1% (95% CI, 14.9%-17.3%) lower 30-day hospitalizations (postimplementation versus preimplementation, 31.4% versus 47.5%; adjusted odds ratio, 0.51 [95% CI, 0.48-0.54]). Among early discharge patients, death or myocardial infarction occurred in 0.5% (41/8780) postimplementation versus 0.4% (22/5383) preimplementation (P=0.61).

Conclusions: hs-HP implementation is associated with increased early discharges without increasing adverse events. These findings support the use of a modified hs-HP to improve chest pain care.

Keywords: acute coronary syndrome; chest pain; myocardial infarction; risk assessments; troponin.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Acute Coronary Syndrome* / diagnosis
  • Acute Coronary Syndrome* / therapy
  • Adult
  • Biomarkers
  • Chest Pain
  • Emergency Service, Hospital
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction* / diagnosis
  • Predictive Value of Tests
  • Troponin

Substances

  • Troponin
  • Biomarkers