Biomechanical Comparison Between Superior Capsular Reconstruction and Lower Trapezius Tendon Transfer in Irreparable Posterosuperior Rotator Cuff Tears

Am J Sports Med. 2024 May;52(6):1419-1427. doi: 10.1177/03635465241235544. Epub 2024 Mar 27.

Abstract

Background: Superior capsular reconstruction (SCR) and lower trapezius tendon transfer (LTT) have recently been used to manage irreparable posterosuperior rotator cuff tears (PSRCTs). There has been a paucity of comparative biomechanical considerations between the 2 procedures.

Purpose: To compare the glenohumeral stability and biomechanical properties between SCR and LTT in PSRCTs involving the entire infraspinatus tendon region.

Study design: Controlled laboratory study.

Methods: Eight fresh-frozen cadaveric shoulders were tested at 0°, 20°, and 40° of shoulder abduction. Maximum internal, external, and total humeral range of motion (ROM), superior translation of the humeral head, and subacromial contact characteristics were compared among 4 conditions: (1) intact rotator cuff, (2) PSRCTs involving the entire infraspinatus tendon region, (3) LTT using Achilles allograft (12 N and 24 N of loading), and (4) SCR using fascia lata allograft.

Results: Although a decrease in total ROM was noted in LTT with 12 N compared with the tear condition, LTT with both 12 N and 24 N as well as SCR did not restrict total rotational ROM compared with the intact condition. LTT had decreased total ROM compared with tear condition at 20° of abduction (P = .042), while no significant decrease was confirmed at all abduction angles after SCR. SCR and LTT with 24 N decreased superior translation compared with the PSRCT condition at 0° and 20° of abduction (P < .037) but not significantly at 40° of abduction, whereas LTT with a 24-N load decreased glenohumeral superior translation at all abduction angles (P < .039). Both SCR and LTT decreased subacromial contact pressure compared with the tear condition (P < .014) at all abduction angles. SCR decreased subacromial contact pressure at 0° and 40° of abduction (P = .019 and P = .048, respectively) compared with LTT with 12 N of loading, while there was no difference between SCR and LTT with 24 N of loading in all abduction angles. SCR increased the contact area compared with the PSRCT condition at all abduction angles (P < .023), whereas LTT did not increase the contact area.

Conclusion: SCR and LTT decreased glenohumeral superior translation and contact pressure compared with PSRCT conditions. The LTT was superior to SCR in terms of superior translation of the humeral head at a higher shoulder abduction angle, whereas the SCR showed more advantageous subacromial contact characteristics compared with LTT.

Clinical relevance: These biomechanical findings provide insights into these 2 fundamentally different procedures for the treatment of young and active patients with PSRCTs involving the entire infraspinatus tendon region.

Keywords: biomechanical comparison; irreparable posterosuperior rotator cuff tear; lower trapezius tendon transfer; superior capsular reconstruction.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Biomechanical Phenomena
  • Cadaver*
  • Fascia Lata / transplantation
  • Female
  • Humans
  • Male
  • Middle Aged
  • Plastic Surgery Procedures / methods
  • Range of Motion, Articular*
  • Rotator Cuff / surgery
  • Rotator Cuff Injuries* / surgery
  • Shoulder Joint* / physiology
  • Shoulder Joint* / physiopathology
  • Shoulder Joint* / surgery
  • Superficial Back Muscles / transplantation
  • Tendon Transfer* / methods