Factors associated with cardiac implantable electronic device-related infections, New South Wales, 2016-21: a retrospective cohort study

Med J Aust. 2024 May 6. doi: 10.5694/mja2.52302. Online ahead of print.

Abstract

Objectives: To quantify the rate of cardiac implantable electronic device (CIED)-related infections and to identify risk factors for such infections.

Design: Retrospective cohort study; analysis of linked hospital admissions and mortality data.

Setting, participants: All adults who underwent CIED procedures in New South Wales between 1 January 2016 and 30 June 2021 (public hospitals) or 30 June 2020 (private hospitals).

Main outcome measures: Proportions of patients hospitalised with CIED-related infections (identified by hospital record diagnosis codes); risk of CIED-related infection by patient, device, and procedural factors.

Results: Of 37 675 CIED procedures (23 194 men, 63.5%), 500 were followed by CIED-related infections (median follow-up, 24.9 months; interquartile range, 11.2-40.8 months), including 397 people (1.1%) within twelve months of their procedures, and 186 of 10 540 people (2.5%) at high risk of such infections (replacement or upgrade procedures; new cardiac resynchronisation therapy with defibrillator, CRT-D). The overall infection rate was 0.50 (95% confidence interval [CI], 0.45-0.54) per 1000 person-months; it was highest during the first month after the procedure (5.60 [95% CI, 4.89-6.42] per 1000 person-months). The risk of CIED-related infection was greater for people under 65 years of age than for those aged 65-74 years (adjusted hazard ratio [aHR], 1.71; 95% CI, 1.32-2.23), for people with CRT-D devices than for those with permanent pacemakers (aHR, 1.46; 95% CI, 1.02-2.08), for people who had previously undergone CIED procedures (two or more v none: aHR, 1.51; 95% CI, 1.02-2.25) or had CIED-related infections (aHR, 11.4; 95% CI, 8.34-15.7), or had undergone concomitant cardiac surgery (aHR, 1.62; 95% CI, 1.10-2.39), and for people with atrial fibrillation (aHR, 1.33; 95% CI, 1.11-1.60), chronic kidney disease (aHR, 1.54; 95% CI, 1.27-1.87), chronic obstructive pulmonary disease (aHR, 1.37; 95% CI, 1.10-1.69), or cardiomyopathy (aHR 1.60; 95% CI, 1.25-2.05).

Conclusions: Knowledge of risk factors for CIED-related infections can help clinicians discuss them with their patients, identify people at particular risk, and inform decisions about device type, upgrades and replacements, and prophylactic interventions.

Keywords: Cardiac pacing, artificial; Cardiovascular infections; Risk factors.