Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2003 2
2004 2
2005 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

5 results

Results by year

Filters applied: . Clear all
Page 1
Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: insights from serial intravascular ultrasound analysis in the TAXUS II study.
Aoki J, Colombo A, Dudek D, Banning AP, Drzewiecki J, Zmudka K, Schiele F, Russell ME, Koglin J, Serruys PW; TAXUS II Study Group. Aoki J, et al. Circulation. 2005 Dec 20;112(25):3876-83. doi: 10.1161/CIRCULATIONAHA.105.558601. Epub 2005 Dec 12. Circulation. 2005. PMID: 16344384 Clinical Trial.
Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial.
Tanabe K, Serruys PW, Degertekin M, Guagliumi G, Grube E, Chan C, Munzel T, Belardi J, Ruzyllo W, Bilodeau L, Kelbaek H, Ormiston J, Dawkins K, Roy L, Strauss BH, Disco C, Koglin J, Russell ME, Colombo A; TAXUS II Study Group. Tanabe K, et al. Circulation. 2004 Jan 20;109(2):196-200. doi: 10.1161/01.CIR.0000109137.51122.49. Epub 2003 Dec 22. Circulation. 2004. PMID: 14691036 Clinical Trial.
Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions.
Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, Dudek D, Fort S, Schiele F, Zmudka K, Guagliumi G, Russell ME; TAXUS II Study Group. Colombo A, et al. Circulation. 2003 Aug 19;108(7):788-94. doi: 10.1161/01.CIR.0000086926.62288.A6. Epub 2003 Aug 4. Circulation. 2003. PMID: 12900339 Clinical Trial.
Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial.
Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, Bonnier J, Lablanche JM, Siminiak T, Nordrehaug J, Figulla H, Drzewiecki J, Banning A, Hauptmann K, Dudek D, Bruining N, Hamers R, Hoye A, Ligthart JM, Disco C, Koglin J, Russell ME, Colombo A; TAXUS II Study Group. Tanabe K, et al. Circulation. 2005 Feb 22;111(7):900-5. doi: 10.1161/01.CIR.0000155607.54922.16. Epub 2005 Feb 14. Circulation. 2005. PMID: 15710761 Clinical Trial.
Vascular responses at proximal and distal edges of paclitaxel-eluting stents: serial intravascular ultrasound analysis from the TAXUS II trial.
Serruys PW, Degertekin M, Tanabe K, Russell ME, Guagliumi G, Webb J, Hamburger J, Rutsch W, Kaiser C, Whitbourn R, Camenzind E, Meredith I, Reeves F, Nienaber C, Benit E, Disco C, Koglin J, Colombo A; TAXUS II Study Group. Serruys PW, et al. Circulation. 2004 Feb 10;109(5):627-33. doi: 10.1161/01.CIR.0000112566.87022.32. Circulation. 2004. PMID: 14769685 Clinical Trial.